How To Test A Limit Switch On A Furnace: Step-by-Step Diagnostic Guide

How To Test A Limit Switch On A Furnace: Step-by-Step Diagnostic Guide

Carrier Furnace Fan Limit Switch Location at Jeffrey Mangano blog

Testing a furnace limit switch requires isolating the component and using a multimeter to verify electrical continuity across its terminals. A functional high limit switch is a normally closed device that should show a resistance reading of nearly zero ohms at room temperature; a reading of infinite resistance or "OL" indicates the switch has tripped or failed, necessitating a thorough inspection of the system's airflow or an immediate component replacement.


Essential Preparation and HVAC Diagnostic Equipment

Before attempting to diagnose internal furnace components, it is critical to understand the role of the limit switch. This safety device monitors the temperature of the heat exchanger. If the temperature exceeds a pre-set threshold—usually due to restricted airflow—the switch opens the circuit, cutting power to the gas valve to prevent a fire or heat exchanger damage. Most modern high-limit switches are "normally closed" (NC), meaning they allow electricity to flow until a specific temperature is reached.

To perform an accurate test, you must have a baseline understanding of your furnace's specific sequence of operations. A failing limit switch often manifests as "short cycling," where the furnace turns on and off rapidly, or a situation where the indoor blower fan runs continuously even when the thermostat is set to "auto."



Required Tools and Technical Specifications



  • Digital Multimeter: Capable of measuring Ohms (Ω) and AC Voltage (VAC).
  • Nut Drivers: Typically 1/4-inch and 5/16-inch sizes for removing furnace access panels and switch mounting screws.
  • Non-Contact Voltage Tester: To verify the absence of electrical current before handling wires.
  • Bright LED Flashlight: For locating the switch within the darkened interior of the blower or burner compartment.
  • Needle-Nose Pliers: For removing tight spade connectors from the switch terminals.
  • Prerequisite Standards: Familiarity with the furnace's wiring diagram (usually found on the inside of the blower door) and basic electrical safety protocols, including Lockout/Tagout (LOTO) practices.
  • Estimated Duration: 20 to 45 minutes.
  • Budget Benchmark: $0 (Diagnostic) to $25–$60 (Replacement parts).

Systematic Workflow for Testing a Furnace Limit Switch

Properly diagnosing a limit switch involves both static (power off) and dynamic (power on) testing. While the continuity test is the industry standard for identifying a dead component, a voltage drop test can help identify intermittent failures or "nuisance trips" caused by aging thermal discs.



Step 1: Power Isolation and Safety Verification

Safety is the absolute priority when working with HVAC equipment. A furnace utilizes both high-voltage (120V) for the motor and low-voltage (24V) for the control circuit.



  1. Switch the thermostat to the "Off" position.
  2. Locate the furnace power switch (usually a light switch on the side of the unit or a nearby wall) and flip it to the "Off" position.
  3. Turn off the corresponding circuit breaker in the main electrical panel.
  4. Remove the upper and lower furnace access panels.
  5. Use a non-contact voltage tester on the wires entering the furnace to ensure no electrical current is present.


Step 2: Locating and Inspecting the Limit Switch

The high limit switch is typically mounted on the firewall of the furnace, positioned so its sensing element (a long probe or a flat thermal disc) sits directly in the path of the heat exchanger's air.



  1. Look for a small, circular or rectangular component with two wires attached to it. It is usually located near the top of the burner compartment or just above the heat exchanger.
  2. Check the part for a manual reset button. Some limit switches feature a small red button in the center. If this button has popped out, the switch has tripped. Press it to reset it, but remember that a tripped switch is a symptom of a larger problem like a dirty filter.
  3. Conduct a visual inspection. Look for signs of scorching, melted plastic, or corrosion on the terminals. If the casing is cracked, the switch must be replaced regardless of the multimeter readings.


Step 3: Disconnecting Terminals for Accurate Testing

To get an accurate resistance reading, you must isolate the switch from the rest of the furnace's control circuit. If you leave the wires connected, the multimeter may "back-feed" through the transformer or gas valve, giving you a false continuity reading.



  1. Take a photo of the wiring configuration for reference during reassembly.
  2. Use needle-nose pliers to gently pull the spade connectors off the two terminals of the limit switch.
  3. Ensure the disconnected wires do not touch any metal parts of the furnace frame.


Step 4: The Static Continuity Test

This is the most definitive way to tell if a limit switch is physically broken.



  1. Turn your digital multimeter to the lowest Ohms (Ω) setting or the continuity setting (the icon that looks like a sound wave).
  2. Touch the two multimeter probes together to ensure the meter is working; it should read 0.0 to 0.3 ohms and/or beep.
  3. Place one probe on each of the two terminals on the limit switch.
  4. Analyze the Results:

    • 0.0 to 0.5 Ohms: The switch is closed and functioning correctly (at room temperature).
    • OL or Infinite Resistance: The switch is open. Since a limit switch should be closed when cold, this indicates a permanent internal failure or a tripped manual reset.

Warning: If the switch shows continuity while the furnace is cold, but the furnace is still throwing a "Limit Switch Open" error code on the control board, the issue may be a loose wire, a faulty control board, or an "intermittent open" that only occurs when the switch vibrates or warms up slightly.



Step 5: Testing During Operation (Voltage Drop Method)

If the continuity test passes but you suspect the switch is tripping prematurely during the heating cycle, you can perform a live voltage test. This requires extreme caution as the system will be energized.



  1. Reattach the wires to the limit switch.
  2. Restore power to the furnace and set the thermostat to call for heat.
  3. Set your multimeter to AC Volts (at least 50V range).
  4. Place one probe on each terminal of the switch while it is connected.
  5. Interpret the Voltage:

    • 0 Volts AC: This is the desired reading. It means the switch is closed, and there is no "potential difference" across it because electricity is flowing through it freely.
    • 24 Volts AC: This means the switch has opened. If this happens shortly after the burners ignite, the furnace is overheating, or the switch is "weak" and opening at a lower temperature than its factory rating.

Pro-Tip: If the switch opens (reads 24V) within three minutes of operation, check your air filter and blower motor immediately. Restricted airflow is the cause of 90% of limit switch trips.


How to Tell If Your Furnace Limit Switch Is Bad | Comfort Bros

How to Tell If Your Furnace Limit Switch Is Bad | Comfort Bros

Standard Temperature Ratings and Technical Specifications

Furnace limit switches are categorized by their "L" (Limit) rating. This number indicates the temperature at which the switch will open and break the circuit. Understanding these codes is essential when ordering a replacement part to ensure the safety profile of the furnace remains intact.



Switch Code Open Temperature (°F) Close Temperature (°F) Typical Application
L140-20 140°F 120°F Low-profile horizontal furnaces
L150-40 150°F 110°F Standard Upflow Residential Furnaces
L175-40 175°F 135°F High-efficiency condensing units
L200-40 200°F 160°F Heavy-duty or older cast iron exchangers
Fan Limit (Dial) Adjustable (130°F+) Adjustable (90°F+) Vintage gravity or forced-air furnaces

Troubleshooting Common Limit Switch Failures

Diagnosing the switch is only half the battle; you must also determine why the switch failed or why it keeps tripping. A limit switch rarely fails on its own; it usually dies because it has been forced to "cycle" (open and close) hundreds of times due to an underlying system issue.



  • The Switch is "Open" (No Continuity) but the Furnace is Cold



    • Root Cause: The internal bimetallic disc has snapped or fatigued, or a manual reset button has not been depressed.
    • Actionable Fix: Check for a reset button. If none exists, or if resetting doesn't restore continuity, replace the switch with one matching the exact "L" rating of the original.
  • The Switch Trips Repeatedly After 5 Minutes of Heating



    • Root Cause: Severe airflow restriction causing the heat exchanger to reach unsafe temperatures. This is often caused by a dirty 1-inch pleated filter or a blocked return air grille.
    • Actionable Fix: Replace the air filter with a fresh one. Ensure all supply vents in the house are open. Check the evaporator coil (if you have AC) for dust buildup that could be blocking the furnace's "exhaust" air.
  • The Blower Fan Runs Constantly and Never Shuts Off



    • Root Cause: Many furnace control boards are programmed to run the blower fan at high speed if they detect an open limit switch circuit as a "fail-safe" to cool down the heat exchanger.
    • Actionable Fix: Perform the Ohm test. If the switch is open (OL), the board thinks the furnace is melting and will run the fan forever to prevent a fire. Replace the switch to restore normal logic to the control board.
  • Intermittent "Limit Circuit" Error Codes on the Control Board



    • Root Cause: Loose "Molex" connectors on the control board or a vibrating wire that momentarily loses contact.
    • Actionable Fix: Inspect the entire wire run from the control board to the limit switch. Tighten the female spade connectors using pliers to ensure a "bite" on the switch terminals.

Frequently Asked Questions



Can I bypass a limit switch to get heat temporarily?

No, you should never bypass or "jump out" a limit switch. This device is a critical safety component designed to prevent the heat exchanger from cracking or catching fire; bypassing it can lead to carbon monoxide leaks or a structural house fire.



How do I know if my limit switch is manual or automatic?

A manual reset limit switch features a small, usually red, button located between the two wire terminals. If your switch has a smooth face or a solid plastic housing with no button, it is an automatic reset switch that should close itself once it cools down.



What causes a limit switch to go bad?

While mechanical failure is possible, most limit switches fail due to "soot" buildup on the sensor or metal fatigue in the bimetallic disc. This fatigue happens when the switch is forced to open and close repeatedly because of poor airflow or an oversized furnace.



How much does it cost to replace a furnace limit switch?

If you perform the work yourself, a replacement limit switch typically costs between $15 and $50 depending on the model. A professional HVAC technician will usually charge between $150 and $300, which includes the diagnostic fee and the part.



Why does my new limit switch keep tripping?

If a new switch continues to trip, the problem is not the switch; it is the furnace. Common culprits include a failing blower motor capacitor, a dirty secondary heat exchanger, or an incorrectly set "gas pressure" that is causing the burners to run too hot.

Contact a Licensed HVAC Professional

If your limit switch continues to fail after replacement or if you discover cracks in your heat exchanger during the inspection process, professional intervention is required to ensure home safety. Reach out to a certified technician to perform a static pressure test and combustion analysis to identify the root cause of your furnace's overheating issues.