How To Tell If The Compressor Is Bad On A Refrigerator: A Technical Diagnostic Guide

How To Tell If The Compressor Is Bad On A Refrigerator: A Technical Diagnostic Guide

How To Test A Refrigerator Compressor at Katie Jenkins blog

The refrigerator compressor is the heart of the sealed system, responsible for circulating refrigerant to maintain optimal internal temperatures. A failing compressor typically manifests through audible mechanical rattling, intermittent cycling, or a complete inability to pull the evaporator temperature below ambient levels despite the condenser fan and evaporator fan operating correctly.


Essential Diagnostic Preparation and Equipment Requirements

Before attempting to diagnose a compressor, ensure the appliance is disconnected from the power source to mitigate electrical hazards. Troubleshooting a compressor requires a balance of mechanical intuition and precise electrical testing. Because the compressor is a hermetically sealed component, internal mechanical failure often necessitates professional sealed-system repair, while electrical failures—such as a tripped start relay or a grounded winding—are manageable with basic diagnostic tools.



  • Essential Equipment: A high-quality digital multimeter with resistance (Ohms) testing capabilities, a set of insulated screwdrivers, a clamp meter for measuring amperage (optional but recommended), and a flashlight.
  • Prerequisite Knowledge: Understanding of basic refrigeration cycles and electrical safety protocols regarding capacitors and high-voltage connections.
  • Estimated Duration: 30 to 45 minutes for a full electrical and mechanical diagnostic procedure.
  • Safety Standards: Always discharge the start capacitor (if present) before touching terminals, and never attempt to bypass factory safety thermal overloads.

Systematic Compressor Diagnostic Workflow



Step 1: Evaluating Operational Auditory and Thermal Signs

Listen closely to the area behind the refrigerator. A functional compressor should produce a consistent, low-frequency hum. If you hear a series of rapid "clicks" followed by silence, the compressor is likely trying to start but failing, which points to a problem with the start relay or the capacitor rather than the compressor motor itself. Check the compressor shell temperature; if it is excessively hot to the touch (exceeding 180 degrees Fahrenheit), the unit may be experiencing a thermal overload trip.



Step 2: Testing Electrical Continuity of the Windings

Access the compressor terminals located behind the access panel at the lower rear of the unit. Remove the start relay and capacitor assembly to expose the three pins—Common (C), Start (S), and Run (R). Set your multimeter to the Ohms (Resistance) setting. You must measure the resistance between each pair of pins: C to S, C to R, and S to R.

Pro-Tip: The sum of the resistance between the Common-to-Start and Common-to-Run pins should approximately equal the total resistance measured between the Start and Run pins. If your meter displays "OL" (Open Loop) or infinite resistance on any pair, the internal windings are broken, confirming a catastrophic compressor failure.



Step 3: Checking for Grounded Winding Faults

A grounded compressor occurs when the internal insulation on the motor windings degrades, allowing electrical current to leak into the compressor housing. Set your multimeter to the lowest resistance setting. Place one probe on a clean, unpainted portion of the copper suction line or the compressor housing itself, and touch the other probe to each of the three compressor pins individually. If the meter registers any continuity (a numeric value instead of "OL"), the compressor is grounded and must be replaced.



Step 4: Verifying the Start Relay and Capacitor

Before condemning the compressor, isolate the start relay. Shake the relay near your ear; a rattling sound often indicates a burnt-out or stuck internal contact. Use your multimeter to test for continuity across the relay terminals in their upright position. If the relay fails to show continuity where it should, or if the run capacitor tests outside of its microfarad (uF) rating, the compressor may simply be lacking the necessary torque to initiate its rotation.

Warning: Never attempt to start a compressor by bypassing the thermal overload protector. This device is the only component preventing a motor fire if the compressor is seized or the windings are shorted.


3 In 1 Refrigerator Relay , How To Tell If the Refrigerator Start Relay ...

3 In 1 Refrigerator Relay , How To Tell If the Refrigerator Start Relay ...

Compressor Diagnostic Parameters and Failure Indicators



Component Test Normal Reading (Ohmic) Failure Threshold Diagnostic Meaning
Common-to-Start 3 to 15 Ohms Open (OL) Broken internal start winding
Common-to-Run 1 to 5 Ohms Open (OL) Broken internal run winding
Pin-to-Ground Infinite (OL) Any measurable value Grounded motor (dead unit)
Start Capacitor Specified uF +/- 10% 0 uF or Shorted Inability to generate start torque

Common Failure Scenarios and Field Rectification



  • The Click-of-Death Cycle: The compressor clicks on and off every few minutes.

    • Root Cause: The start relay or capacitor is faulty, or the compressor is seized (locked rotor).
    • Actionable Fix: Replace the start relay and capacitor set. If the new set clicks immediately, the compressor mechanical assembly is seized and requires a full system replacement.
  • Compressor Runs Continuously but Refrigerator Stays Warm: The unit never cycles off, and the freezer temperature is rising.

    • Root Cause: A sealed system leak resulting in low refrigerant charge, or an inefficient compressor valve set.
    • Actionable Fix: Check the frost pattern on the evaporator coil. If only a small section is frosted, it indicates a refrigerant leak or restriction. This requires professional EPA-certified recovery and system evacuation.
  • Unit Trips Household Circuit Breaker:

    • Root Cause: The compressor motor has a grounded winding that is shorting to the chassis.
    • Actionable Fix: Perform a ground test as outlined in Step 3. If the compressor is confirmed as grounded, the component is irrecoverable and requires replacement.

Frequently Asked Questions



Can I replace a refrigerator compressor myself?

Replacing a compressor requires specialized tools, including an oxy-acetylene torch, a vacuum pump, and a manifold gauge set, plus certification to handle refrigerants. Because it involves breaking the sealed system, it is generally considered beyond the scope of standard DIY maintenance.



What causes a refrigerator compressor to go bad?

The most common causes include age-related wear on internal bearings, excessive heat caused by dirty condenser coils that increase operating pressure, and electrical surges that damage the start components or motor windings.



Is it worth repairing a compressor or should I replace the fridge?

If the refrigerator is less than 7–10 years old and the compressor is covered under a manufacturer’s sealed system warranty, repair is often cost-effective. However, out-of-warranty replacement of a compressor is expensive and often approaches the cost of a new, more energy-efficient appliance.



How long should a refrigerator compressor last?

A well-maintained compressor should function for 12 to 20 years. Regular cleaning of the condenser coils every six months is the single most effective way to extend the lifespan of the compressor by reducing thermal stress.

Professional Diagnostic Support

If you have verified the electrical integrity of the start relay and the motor windings and the unit still fails to cycle properly, contact a licensed technician to perform an amp-draw and suction-pressure test. Secure your kitchen's longevity by scheduling a preventative maintenance check-up to ensure your cooling system operates within factory specifications.