Operating The 1997 Rexhall Aerbus: A Comprehensive Guide To Onboard Systems
Mastering the 1997 Rexhall Aerbus requires a systematic understanding of the coach's integrated electrical, plumbing, and climate control infrastructure. This guide covers the essential startup sequences, utility management protocols, and safety overrides necessary to operate your vintage Class A motorhome to peak mechanical efficiency.
Essential Preparation and Operational Prerequisites
Operating a 1997 Rexhall Aerbus is an exercise in resource management. Before engaging any major system, you must ensure the coach is leveled and stabilized, as the refrigerator absorption cooling units and slide-out mechanisms are highly sensitive to chassis pitch. Prior to departure or arrival, verify your primary utility connections, fuel levels, and chassis fluid benchmarks.
- Essential Equipment: A 30-amp or 50-amp dogbone adapter, a high-quality water pressure regulator (set to 40-50 PSI), a non-contact voltage tester, and a basic multimeter for troubleshooting electrical continuity.
- Foundational Knowledge: Familiarity with the coach’s battery isolation switch, the location of the converter/charger unit, and the specific sequence for igniting the propane-fired water heater.
- Budgetary Benchmarks: Anticipate a baseline maintenance overhead of 2-5% of the vehicle’s current value annually to cover sealants, filter replacements, and electrical contact cleaning.
- Operational Duration: Initial setup upon arrival typically requires 20 to 30 minutes for a single operator to complete a full utility hookup and system initialization.
Sequential Procedures for Aerbus System Activation
Step 1: Chassis and House Electrical Initialization
The 1997 Aerbus utilizes a split electrical system. Locate the battery disconnect switches, typically found near the entry step or in the battery compartment. Ensure both the chassis and house battery switches are in the "on" position. If the coach is stored, these must be engaged to prevent parasitic drain on the starter batteries. If you are plugged into shore power, verify the converter is humming and the battery monitor indicates a charging state.
Pro-Tip: If the interior lights are flickering while on shore power, check the converter fuse panel. Oxidation on the glass-style fuses is a common point of failure for 90s-era RVs; replace them with new ceramic-style equivalents to improve conductivity.
Step 2: Propane System and Appliance Ignition
Before activating appliances, open the primary LP tank valve slowly to prevent the automatic excess flow safety device from tripping. Walk to the range and ignite a burner to purge air from the lines. Once the flame is consistent, you may proceed to cycle the refrigerator to "Auto" or "Gas" mode and the water heater to the "On" position.
Warning: Never attempt to light the furnace or water heater if you smell the distinct rotten-egg odor of mercaptan. Immediately close the LP tank valve and evacuate the coach until the leak is identified by a certified RV technician.
Step 3: Fresh Water and Sanitation Management
Connect your potable water hose to the city water inlet using a pressure regulator. Once connected, open a cold-water faucet to bleed air until the stream is steady. If relying on the onboard fresh water tank, ensure the water pump switch is activated. For the black and gray water tanks, always keep the dump valves closed while camping to maintain a fluid seal, opening them only when the tanks reach 75% capacity to ensure a forceful, gravity-assisted discharge.
Step 4: Climate Control and Ventilation
The 1997 Aerbus is typically equipped with a roof-mounted air conditioning unit and a floor-ducted LP furnace. Operate the thermostat by selecting the "Fan" mode to high or low before switching to "Cool" or "Heat." If the furnace blower starts but the burner fails to ignite, verify the propane supply and clear the burner exhaust port of any mud-dauber nests or debris, as obstruction will trigger the sail switch safety shutoff.
95 Rexhall Aerbus for Sale in Orange, CA - OfferUp
Technical Specifications and Operational Thresholds
| System | Component Type | Operating Standard | Maintenance Interval |
|---|---|---|---|
| Electrical | Converter/Charger | 13.2V - 14.4V Output | Inspect terminals annually |
| Fresh Water | Demand Pump | 30 - 45 PSI cut-off | Sanitize system biannually |
| Sanitation | Black/Gray Tanks | Capacity: 40-50 Gallons | Flush monthly |
| Climate | Propane Furnace | 25,000 - 35,000 BTU | Clean blower fan yearly |
| Refrigeration | Absorption Unit | Level: +/- 3 Degrees | Clean burner flue biannually |
Troubleshooting Common Operational Failures
- Root Cause: Shore Power Connection Failure. If the coach has no power when plugged in, the shore power cord contacts may be corroded or the main breaker on the pedestal has tripped.
- Actionable Fix: Use a multimeter to verify 120V AC at the pedestal. If the pedestal is live, clean the male prongs on your power cord with fine-grit sandpaper and inspect the automatic transfer switch (ATS) for stuck contactors.
- Root Cause: No Hot Water on Propane. The electronic ignition module often fails due to moisture or a compromised ground connection.
- Actionable Fix: Remove the outer water heater access panel and check the spark igniter for soot buildup. Ensure the ground wire attached to the burner assembly is tight and free of rust.
- Root Cause: Dim Interior Lighting. Oxidation on the 12V distribution block or a discharged house battery.
- Actionable Fix: Tighten all lug connections at the distribution panel. If the battery voltage is below 12.2V under load, use a deep-cycle charger to bring the battery back to full capacity before testing the system again.
Frequently Asked Questions
Why does my refrigerator stop working when the RV is not perfectly level?
The 1997 Aerbus uses an absorption cooling system that relies on gravity to circulate refrigerant through the coils. If the coach is not level, the solution can pool in the pipes, creating a blockage that prevents the cycle from completing, which can permanently damage the cooling unit.
How do I switch between shore power and the generator?
Most 1997 Aerbus models are equipped with an automatic transfer switch that prioritizes the generator. When you start the generator, the switch will click within 30 seconds and automatically shift the internal power bus to generator power; no manual intervention is required.
What is the purpose of the water heater bypass valve?
The bypass valve is located behind the water heater and is used during winterization. It allows you to isolate the water heater tank so that you do not have to fill it with six to ten gallons of RV antifreeze, which is both expensive and difficult to flush out in the spring.
How often should I sanitize the fresh water tank?
You should sanitize the fresh water tank at the beginning of every season or if the coach has sat idle for more than two months. Use a ratio of one-quarter cup of household bleach for every 15 gallons of tank capacity, fill the system, let it sit for 24 hours, and flush thoroughly.
Ensure Longevity for Your Rexhall Aerbus
Regularly inspecting your roof seals and window caulking is the single most important action you can take to preserve the structural integrity of your 1997 Aerbus. Schedule a comprehensive system walkthrough every spring to ensure your vintage coach remains a reliable platform for your travels.