How To Reset An Electric Furnace: A Comprehensive HVAC Troubleshooting Guide

How To Reset An Electric Furnace: A Comprehensive HVAC Troubleshooting Guide

How To Change Filter On Lennox Furnace | Gas Furnace

To reset an electric furnace, you must cycle the dedicated double-pole circuit breaker in your main electrical panel and press the manual reset button located on the blower motor or the primary limit switch inside the unit’s cabinet. This procedure clears minor electrical glitches and thermal overload trips, but persistent tripping usually indicates restricted airflow or a failing heating element sequencer that requires technical intervention.


Safety Protocols and Essential Diagnostic Tools for Furnace Maintenance

Before attempting to interact with the internal components of an electric furnace, it is vital to understand that these systems operate on high-voltage circuits, typically 240 volts. Safety is the absolute priority, as improper handling of the electrical cabinet can result in severe shock or arc flash. The reset process is generally straightforward, but it must be performed with a systematic approach to prevent damaging sensitive control boards or heating strips.



Required Equipment and Prerequisites



  • Essential Tools: A non-contact voltage tester, a Philips-head or 5/16" nut driver (for removing the access panel), and a high-intensity flashlight.
  • Mandatory Knowledge: You must be able to identify your furnace’s dedicated breaker—usually a 60-amp to 100-amp double-pole switch—in the home's main service panel.
  • Estimated Duration: 15 to 30 minutes.
  • Budget Benchmark: $0 for a manual reset; $50–$150 if a basic component like a limit switch or capacitor requires replacement.

Chronological Procedure for Safely Resetting Your Heating System

The following steps outline the professional-grade workflow for restoring power and functionality to an electric furnace that has entered a lockout state.



Step 1: Initial Thermostat Calibration and Verification

Before diving into the hardware, ensure the issue is not a simple communication error between the thermostat and the furnace control board. Turn the thermostat to the "Off" position. If your thermostat is battery-operated, replace the batteries now to ensure a strong signal. Wait 30 seconds, then set the mode to "Heat" and raise the temperature at least five degrees above the current room temperature. If you do not hear the "click" of the relay or the hum of the blower motor starting within two minutes, proceed to the mechanical reset.



Step 2: Cycling the Main Electrical Service Breaker

Electric furnaces do not have a simple "on/off" switch like a lamp; they rely on heavy-duty circuit breakers. Locate your home’s electrical panel and find the switches labeled "Furnace" or "Air Handler."



  • Look for a breaker that is in the "neutral" or "tripped" position (halfway between ON and OFF).
  • Even if the breaker looks like it is in the ON position, flip it completely to the OFF position.
  • Wait for at least 60 seconds. This allows any residual electrical charge in the furnace capacitors to dissipate.
  • Flip the breaker firmly back to the ON position.

Warning: If the breaker immediately snaps back to the OFF position, do not attempt to force it. This indicates a "hard short" in the wiring or a grounded heating element, which poses a significant fire risk.



Step 3: Accessing the Internal Reset Button

Most modern electric furnaces are equipped with a secondary safety reset button located inside the furnace cabinet. This is often tied to the blower motor or the high-limit switch.



  1. Ensure the power is turned off at the breaker before opening the furnace.
  2. Use your nut driver to remove the screws securing the upper and lower access panels.
  3. Search for a small, usually red or yellow, button.

    • On the Blower Motor: Look for a button on the side or back of the motor housing. This is a thermal overload protector.
    • On the Limit Switch: This is usually located near the heating element assembly (the "heat strips").
  4. Press the button firmly. If you feel or hear a click, the safety limit had been tripped due to overheating.


Step 4: Inspecting the Air Filtration System

A primary reason for a furnace needing a reset is "limit tripping." When air cannot flow freely over the electric heat strips, the internal temperature skyrockets, triggering the safety switch to prevent a fire.



  • Slide out your air filter. If it is coated in a grey layer of dust or dander, it must be replaced.
  • Check that all supply registers (vents) in your home are open. Closing more than 20% of your home's registers can cause backpressure and overheating in an electric furnace.


Step 5: System Re-Engagement and Monitoring

Replace the furnace access panels, ensuring the safety interlock switch (a small peg that is depressed when the door is closed) is fully engaged. Turn the power back on at the breaker panel. Return to your thermostat and set it to heat. Monitor the furnace for the first 15 minutes of operation. Listen for unusual humming, grinding, or the smell of "ozone" or burning plastic, which could indicate a failing sequencer or a blower motor capacitor reaching the end of its functional life.

Pro-Tip: If you smell a "dusty" burning scent during the first reset of the season, this is typically just the nichrome wire heating elements burning off accumulated settled dust and is not a cause for alarm. However, if the smell persists for more than 20 minutes, shut the system down.


How To Reset A Furnace With the Reset Button and Where is it

How To Reset A Furnace With the Reset Button and Where is it

Technical Specifications and Component Fault Thresholds

The following table details the various components that may necessitate a system reset, including their operational thresholds and typical failure indicators.



Component Primary Function Trip Trigger Reset Methodology
High-Limit Switch Monitors plenum temperature Temperature exceeding 150°F-180°F Manual button or auto-cool down
Circuit Breaker Amperage overload protection Current draw exceeding 60A/100A Manual toggle at service panel
Blower Motor Air distribution/Heat dissipation Internal winding temp > 140°F Manual button on motor housing
Sequencer Staggers heating element activation Stuck "on" or "off" relay Requires part replacement (no reset)
Transformer Low-voltage (24V) supply Short circuit in thermostat wiring Replace internal fuse or unit
Flame/Heat Sensor (In Hybrid Units) Proves ignition Carbon buildup on sensor rod Cleaning with fine abrasive

Common Failure Scenarios and Field Resolutions

Even after a successful reset, underlying mechanical issues may cause the furnace to fail again. Understanding these real-world failure patterns allows for more accurate diagnostics.



Scenario 1: The "Repeating Trip" Syndrome



  • Root Cause: This usually occurs when the blower motor is failing to reach its rated RPMs or the air filter is severely restricted. The heating elements (heat strips) generate immense heat that is not being carried away, causing the high-limit switch to trip repeatedly to prevent the melting of internal components.
  • Actionable Fix: Replace the air filter with a MERV 8 to MERV 11 rated filter. Ensure the blower wheel is clean of debris. If the motor is hot to the touch but the fan is not spinning, the run capacitor likely needs replacement.


Scenario 2: Furnace Resets but Blows Cold Air



  • Root Cause: The 24-volt control circuit is functioning, and the blower is running, but the heating elements are not receiving high-voltage power. This is often caused by a failed sequencer—a small device that staggers the activation of heating strips to prevent a massive power surge.
  • Actionable Fix: Use a multimeter to check for 240V at the heating elements. If 24V is present at the sequencer coil but 240V is not exiting the load side, the sequencer is defective and must be replaced.


Scenario 3: Audible Buzzing Without Heat or Fan



  • Root Cause: A "locked rotor" condition in the blower motor or a failed contactor. The furnace is trying to draw power, but the mechanical resistance is too high, leading to a circuit breaker trip.
  • Actionable Fix: Turn off all power. Manually attempt to spin the blower wheel. If it does not spin freely, the bearings have seized, and the motor requires replacement. If it spins freely, the contactor points may be pitted or welded shut.


Scenario 4: Frequent Breaker Tripping



  • Root Cause: Electric furnaces pull a massive amount of current. Over time, the wire connections at the breaker or the furnace lugs can loosen due to thermal expansion and contraction. Loose connections create resistance, which generates heat and trips the breaker.
  • Actionable Fix: With the main power OFF, inspect the wire lugs for signs of discoloration (pitting/burning). Tighten the lugs to the manufacturer's specified torque (usually measured in inch-pounds) to ensure a solid electrical connection.

Frequently Asked Questions



Why does my electric furnace have a reset button?

The reset button is a safety "fail-safe" designed to kill power to the heating elements if the internal temperature exceeds safe operating limits. It prevents the furnace from becoming a fire hazard in the event of a blower failure or a total blockage of the return air ducts.



How many times can I reset my furnace before calling a pro?

You should only attempt to reset your furnace once. If the system trips a second time, it is a clear signal that a safety limit is being reached or an electrical component is malfunctioning. Repeatedly resetting a furnace can lead to permanent damage to the expensive nichrome heating coils or the control board.



Where is the reset button on a Coleman or Goodman electric furnace?

On most popular brands like Coleman, Goodman, or Rheem, the reset button is located near the blower motor housing or on the limit switch mounted to the heater kit. You will usually need to remove the front service panel to see the small red button.



Can a dirty air filter cause my furnace to need a reset?

Yes, a dirty air filter is the number one cause of furnace resets. It restricts the volume of air passing over the heating elements, causing them to overheat. This triggers the high-limit switch, which shuts down the system and requires a manual reset to resume operation.

Expert HVAC Support and Maintenance

If your electric furnace continues to trip the breaker or fails to produce heat after a reset, professional diagnostic testing is required to ensure system safety. Contact a licensed HVAC technician to perform an amperage draw test and inspect your heating elements for structural integrity.