Relighting a water heater pilot light requires locating the gas control valve, turning it to the off position to clear residual gas, and using the built-in igniter or a long-reach lighter while holding the pilot button down. Following manufacturer specifications and adhering to strict natural gas safety protocols ensures a successful restart without risking combustion hazards.


Pre-Operation & Equipment Checklist

A successful pilot light restart depends on proper preparation, precise tool selection, and a firm understanding of gas safety compliance standards. Before interacting with the appliance, gather the necessary items and verify the operating environment.



  • Essential Gear & Tools: Flashlight, safety glasses, long-reach utility lighter or matches, and a screwdriver if removing an inner access panel.
  • Prerequisite Knowledge & Standards: Familiarity with natural gas or propane odor, adherence to the National Fuel Gas Code (NFPA 54), and a clear understanding of the appliance rating plate located on the outer tank shell.
  • Budget & Duration Benchmarks: Estimated financial cost is zero dollars if tools are on hand; completion time ranges between 10 and 20 minutes depending on thermocouple response times.

Step-by-Step Pilot Relighting Workflow



Step 1: Locate the Gas Control Valve and Inspect for Leaks

Examine the lower section of your tank-style water heater to locate the gas control valve assembly, which typically features settings marked Pilot, On, Off, and a red or black piezoelectric igniter button. Before turning any knobs, perform a comprehensive sniff test around the base of the unit to ensure there is no lingering smell of natural gas or propane.

Warning: If you smell a strong odor of gas, do not attempt to relight the pilot, do not flip any electrical switches, and immediately evacuate the building before calling your local utility provider or emergency services.



Step 2: Turn the Control Valve to the Off Position

Locate the primary temperature and gas control dial and rotate it from its current setting to the OFF position. Wait a minimum of five minutes before proceeding to the next step. This mandatory waiting period allows any unburned gas lingering in the combustion chamber to fully dissipate through the draft hood and flue, preventing a minor minor flashback or sudden ignition.



Step 3: Set the Dial to Pilot and Ignite the Burner

Turn the control dial from OFF to the PILOT position. Locate the pilot button (on modern units) or keep the main dial depressed down firmly. While holding the button or dial down continuously, click the piezoelectric igniter button repeatedly, or insert a long-reach lighter through the sight glass viewing port to apply a flame directly to the pilot assembly. Continue holding the button down for 30 to 60 seconds after the small blue flame appears to allow the thermocouple to generate sufficient millivoltage.

Pro-Tip: If your water heater does not feature an automatic piezoelectric spark igniter, tape a long-reach fireplace match securely to a stick or use an extended utility lighter to maintain a safe distance from the combustion chamber opening during lighting.



Step 4: Verify Flame Stability and Return Valve to On Position

Release the pilot button slowly while watching the pilot flame through the sight glass window. If the flame remains lit and steady, rotate the control dial from the PILOT position to the ON position. Adjust the thermostat dial to your desired hot water temperature, typically recommended between 120 degrees Fahrenheit and 140 degrees Fahrenheit to balance energy efficiency and bacterial mitigation.


How To Light Pilot On Rheem Hot Water Tank | Homeminimalisite.com

How To Light Pilot On Rheem Hot Water Tank | Homeminimalisite.com

Gas Control Valve Settings and Troubleshooting Parameters



Valve Setting Mechanical Function Safety Implication Recommended Action
OFF Completely cuts off gas supply to both pilot and main burner Eliminates combustion risk during maintenance Use during system shutdowns or gas leaks
PILOT Directs gas exclusively to the small pilot assembly Allows manual lighting while bypassing main tank heating Hold down for 60 seconds to heat thermocouple
ON Enables normal automated gas delivery to the main burner Engages tank heating cycles based on thermostat settings Leave in this position for standard daily operation

Common Site Failures & Field Fixes



  • Root Cause: The pilot flame lights immediately upon pressing the igniter, but goes out the exact second the pilot button is released. Actionable Fix: The thermocouple is failing to generate the required 15 to 30 millivolts needed to hold the safety magnetic valve open. Clean the thermocouple tip with fine emery cloth to remove soot buildup, or replace the thermocouple assembly if the internal generator has degraded.
  • Root Cause: No spark is generated when pressing the piezoelectric igniter button on the front control panel. Actionable Fix: Inspect the ceramic electrode wire for cracking, disconnection, or excessive carbon accumulation. Clean the spark gap area or manually light the pilot using a long-reach utility lighter while holding the pilot button down.
  • Root Cause: The pilot light will not ignite at all, and no gas flow can be detected at the pilot burner tube. Actionable Fix: Verify that the main gas supply shutoff valve located on the supply line piping is fully open. If the supply line is open, the gas control valve may be internally blocked or broken, requiring professional replacement by a licensed plumber.

Frequently Asked Questions



How long should I hold the pilot button down when relighting?

You should hold the pilot button down continuously for 30 to 60 seconds after the flame ignites. This duration is required to heat the thermocouple tip, allowing it to produce enough millivoltage to energize the safety magnet and keep the gas valve open automatically.



What should I do if I smell gas near my water heater?

Immediately turn off the main gas supply valve, avoid operating any electrical switches or cellular devices near the area, and evacuate the building. Contact your local gas utility provider or a certified technician immediately from a safe location to inspect the system for leaks.



Why does my water heater pilot light keep going out?

A pilot light that repeatedly extinguishes is typically caused by a dirty or faulty thermocouple, a drafty installation location that blows the flame out, or a restricted combustion air intake filter at the base of the water heater tank. Cleaning the area and replacing worn components usually resolves the issue.



Is it safe to relight a water heater pilot light myself?

Yes, homeowners can safely relight a pilot light by strictly following the manufacturer lighting instructions printed on the side of the tank. However, if you feel uncomfortable handling gas appliances or detect persistent gas odors, you should call a licensed plumbing professional.

Professional Water Heater Maintenance Services

Ensure your home's hot water supply remains reliable and energy-efficient by scheduling an annual safety inspection with our team of certified plumbing technicians. Contact us today to book a comprehensive water heater tune-up, sediment flush, and complete gas safety diagnostic.


How To Relight A Gas Water Heater Pilot Light | Read More

How To Relight A Gas Water Heater Pilot Light | Read More

Read also: Former employees are speaking out against brightspring rescare policies