How To Light The Pilot On A Gas Water Heater: A Step-by-Step Technical Guide

How To Light The Pilot On A Gas Water Heater: A Step-by-Step Technical Guide

How To Light Pilot On Atwood Rv Water Heater at Margaret Cass blog

Lighting the pilot light on a standard gas water heater involves turning the gas control valve to the pilot position, depressing the reset button while applying an external flame or triggering the piezo igniter, and holding it for 30 to 60 seconds to allow the thermocouple to generate sufficient millivoltage. Ensuring proper clearance, checking for gas leaks, and following manufacturer-specific safety protocols are essential before initiating the sequence.


Pre-Operation & Equipment Checklist

Before attempting to relight your gas water heater pilot, it is critical to prepare the workspace, gather necessary tools, and verify that operating conditions are safe. Gas appliances demand absolute respect for safety codes and operational parameters.



  • Essential Gear, Tools, & Materials: Long-reach butane utility lighter or matches, flashlight or headlamp, work gloves, soapy water solution in a spray bottle (for leak detection), and a flathead screwdriver if access panels need adjustment.
  • Mandatory Prerequisite Knowledge & Standards: Familiarity with the appliance's control valve settings (ON, OFF, PILOT), understanding of natural gas or propane odor, and awareness of the National Fuel Gas Code (NFGF) requirements regarding combustion air and clearance distances.
  • Estimated Budget & Duration Benchmarks: Duration is typically 10 to 15 minutes. Financial cost is zero if performed independently by the homeowner, though calling a certified plumber or HVAC technician typically ranges from $100 to $250 for diagnostic and lighting services.

Step-by-Step Pilot Lighting Procedure



Step 1: Locate the Gas Control Valve and Review Safety Labels

Locate the gas control valve situated near the lower front section of the water heater tank. Read the manufacturer instructions printed on the metal jacket of the tank to identify whether your unit utilizes a traditional standing pilot valve or a modern electronic control valve (such as Honeywell or White-Rodgers). Ensure the area is entirely free of flammable liquids, paint thinners, gasoline, or aerosol cans.

Warning: If you smell a strong odor of gas in the room, stop immediately. Do not touch electrical switches, light matches, or operate phones inside the area. Evacuate the premises and utility company immediately from a remote location.



Step 2: Turn the Control Valve to the Off Position

Rotate the main gas control knob from its current position to the OFF setting. For older Honeywell or Robertshaw valves, you may need to depress the knob slightly to turn it past the PILOT stop.

Pro-Tip: Always wait a minimum of 5 to 10 minutes after turning the gas off before attempting to relight. This mandatory dwell time allows any residual unburned gas pooled in the combustion chamber to safely dissipate out of the draft hood or flue.



Step 3: Set the Valve to Pilot and Clear the Line

Turn the gas control knob clockwise or counterclockwise, depending on the model, until the indicator arrow points directly to the PILOT position. Remove the outer burner door and inner combustion chamber access cover (if applicable) to visually inspect the burner assembly using your flashlight.



Step 4: Ignite the Pilot Assembly

If your water heater features a red or black piezo igniter button, press the main gas control knob down firmly while repeatedly clicking the piezo igniter button. For older units without a piezo sparker, keep the control knob firmly depressed with one hand while inserting a long-reach lit match or utility lighter through the sight glass opening to touch the pilot burner head. Continue holding the control knob down firmly for 30 to 60 seconds after the flame ignites. This sustained heat exposure allows the thermocouple tip to reach operating temperature and generate the 15 to 30 millivolts required to hold the safety magnet open inside the gas valve.



Step 5: Release the Knob and Verify Flame Stability

Slowly release the gas control knob. The pilot flame should remain lit and stable inside the combustion chamber. If the pilot flame extinguishes immediately upon releasing the knob, the thermocouple is either failing, improperly positioned in the flame, or the control valve safety circuit has tripped. If the pilot stays lit, turn the control knob counterclockwise to the ON position. Replace all inner and outer access covers securely to ensure proper combustion airflow dynamics.


Water Heater Control Valve and Ignition Specifications



Valve Type Ignition Mechanism Holding Time Required Typical Application
Mechanical Standing Pilot External Match or Piezo Igniter 30 to 60 Seconds Standard efficiency atmospheric tanks
Electronic Gas Control Integrated Piezo / Spark Electrode 10 to 30 Seconds Modern high-efficiency atmospheric tanks
Power Vent / Direct Vent Automated Hot Surface Igniter N/A (Fully Automatic) Induced draft and sealed combustion units

Common Site Failures and Field Fixes

When troubleshooting gas water heater pilot issues, recognizing specific component failures prevents wasted time and potential hazards.



  • Root Cause: The pilot flame lights successfully while holding the button down, but extinguishes the exact moment the button is released.

    • Actionable Fix: The thermocouple tip is either out of alignment with the flame or has failed electrically. Ensure the blue flame envelops the upper third of the thermocouple tip. If alignment is correct and it still drops out, test the millivolt output using a multimeter or replace the thermocouple assembly.
  • Root Cause: The piezo igniter clicks repeatedly, but no spark appears at the pilot head.

    • Actionable Fix: Inspect the ceramic igniter electrode wire for cracks, loose terminal connections, or soot buildup. Clean the electrode spark gap with fine-grit sandpaper and ensure the gap is adjusted to approximately one-eighth of an inch from the pilot hood.
  • Root Cause: Gas fails to flow to the pilot burner entirely when the valve is depressed in the pilot position.

    • Actionable Fix: Verify that the main gas supply shut-off valve on the supply line pipe is fully open. If the supply line is open and gas still fails to reach the pilot orifice, the internal gas control valve diaphragm is likely stuck or defective and requires complete valve replacement by a licensed professional.

Frequently Asked Questions



Why does my water heater pilot light keep going out?

A pilot light typically goes out due to a faulty thermocouple, a drafty installation location that blows the flame out, or a restricted pilot tubing orifice. If the thermocouple generates less than 15 millivolts under flame load, the safety valve automatically cuts off the gas supply. Cleaning the pilot assembly and securing nearby HVAC vents often resolves intermittent outages.



Can I use a regular kitchen match to light my water heater?

Using a standard short kitchen match is dangerous because it requires placing your hand directly inside the combustion access opening close to potential gas accumulation. Always use a long-reach butane utility lighter designed for fireplaces and grills to maintain a safe distance from the burner chamber.



How do I know if my water heater uses natural gas or propane?

You can identify the gas type by checking the rating plate data label affixed to the side of the water heater tank. The label explicitly states the approved fuel source, manifold pressure specifications, and input rating in British Thermal Units (BTUs). Furthermore, propane-fueled heaters feature a distinct brass or stainless steel orifice sizing and are generally installed in homes without municipal natural gas infrastructure.



Is it normal to smell gas when lighting the pilot?

A faint, momentary whiff of gas is acceptable when purging the supply line and holding the valve down prior to ignition. However, a persistent, strong sulfur or rotten egg odor indicates an active gas leak or unburned gas pooling in the room. If this occurs, immediately abort the lighting procedure, ventilate the area, and inspect all pipe joints with soapy water.



What should I do if the burner does not ignite after turning the valve to ON?

If the pilot remains lit but the main burner fails to fire when you turn the temperature dial up, check the thermostat setting or verify that the water temperature inside the tank is already satisfied. If the tank is cold and the burner still will not ignite, the gas control valve thermostat assembly may be defective and require replacement.

Ensure your water heater operates safely and efficiently by scheduling annual preventative maintenance or contacting a licensed plumbing professional if ignition issues persist.


Read also: Why the undercut for guys is the most versatile look in 2024