How To Convert LP Gas Grill To Natural Gas Safely And Efficiently

How To Convert LP Gas Grill To Natural Gas Safely And Efficiently

Ducane Grill Natural Gas Conversion Kit at Kathy Carter blog

Converting a liquid propane grill to run on natural gas requires replacing the orifices to adjust for lower operating pressure and BTU output, alongside installing a dedicated supply hose. Because natural gas operates at roughly half the pressure of propane and demands a larger orifice bore size to deliver equivalent heat, skipping these engineering adjustments will result in dangerously weak flames or complete system failure.


Pre-Operation & Equipment Checklist

Transitioning a liquid propane (LP) grill to a natural gas (NG) utility line is a permanent modification that changes how your appliance manages fuel delivery and combustion. Propane systems pressurize fuel tanks to approximately 100 to 250 psi, which regulators step down to an 11-inch water column (W.C.) at the burner manifold. Natural gas, by contrast, is typically delivered to residential meters at a much lower pressure and regulated down to a 4 to 7-inch W.C. at the appliance connection.

To bridge this operational delta, you must re-engineer the fuel delivery pathways by swapping out restricted LP components for high-flow NG equivalents. Performing this installation incorrectly risks gas leaks, carbon monoxide production, or severe flare-ups.



  • Essential Gear, Tools, and Materials:

    • Conversion kit specific to your grill make and model (includes natural gas orifices and manifold regulator)
    • Natural gas rated quick-disconnect hose assembly (typically 3/8-inch or 1/2-inch inner diameter)
    • Adjustable wrenches and open-end wrench set (usually 1/4-inch to 9/16-inch)
    • Nut driver set or deep well socket set
    • Gas-rated thread sealant (pipe dope approved for natural gas and propane) or yellow PTFE gas tape
    • Leak detection solution (mixture of dish soap and water, or a commercial electronic gas leak detector)
  • Mandatory Prerequisite Knowledge and Standards:

    • Familiarity with ANSI Z21.58/CSA 1.6 standards for outdoor cooking gas appliances.
    • Verification that your home natural gas meter and supply piping can handle the combined peak BTU load of your home appliances plus the grill.
  • Estimated Budget and Duration Benchmarks:

    • Cost: 50 to 150 dollars for conversion kits and specialized hoses (excluding professional gas line installation).
    • Duration: 1 to 2 hours of direct mechanical work.

Step-by-Step Conversion and Installation Workflow



Step 1: Disconnect the Propane Source and Prepare the Chassis

Begin by ensuring the existing liquid propane tank is completely turned off at the valve and detached from the grill regulator. Safely remove the tank from the cabinet and store it outdoors in a well-ventilated area away from direct sunlight and ignition sources. Open the grill hood, remove the cooking grates, heat tents (flavorizer bars), and burner covers to expose the burner tubes and manifold assembly.

Warning: Never attempt any fuel system modifications while a pressurized propane tank is anywhere near the work zone, and ensure all burner control knobs are in the off position.



Step 2: Remove the Existing LP Orifices

Locate the point where the burner tubes attach to the control valves at the rear or underside of the firebox. Each burner features a small brass fitting called an orifice threaded into the end of the valve, which meters the propane into the venturi tube. Using a precision open-end wrench or a deep well socket, carefully unscrew each LP orifice from the valve stem. Take note of which burner corresponds to which valve if your grill features varying BTU outputs across zones (such as a high-heat sear station versus standard burners).



Step 3: Install the Natural Gas Orifices

Select the replacement natural gas orifices included in your manufacturer-approved conversion kit. Natural gas orifices feature a significantly larger bore diameter than LP orifices to compensate for the lower operating pressure of natural gas. Apply a minimal amount of gas-rated thread sealant or wrap yellow gas PTFE tape clockwise around the male threads of the new orifices. Thread the NG orifices onto the valve stems, tightening them snugly with your wrench, but take care not to over-torque and strip the brass threads.



Step 4: Swap or Adjust the Pressure Regulator

Most LP grills include a regulator attached to a flexible hose designed for high-pressure propane tanks. Because natural gas requires a low-pressure regulator, you must either remove the old regulator entirely or adjust/replace it with a natural gas-specific regulator. If your kit specifies an inline NG regulator, mount it downstream of your natural gas supply shut-off valve, paying strict attention to the directional flow arrow stamped on the metal housing. Connect the natural gas quick-disconnect hose assembly from your residential gas stub-out to the newly configured grill manifold inlet.



Step 5: Perform Comprehensive Leak Testing and Flame Tuning

With all physical connections secured, turn on the main natural gas supply valve at your home drop. Brush your dish soap and water solution over every single threaded joint, connection point, regulator seam, and valve stem you touched during the procedure. Watch closely for the formation of growing soap bubbles, which indicate an active gas leak. If bubbles appear, shut off the gas immediately, disassemble the leaking joint, reapply thread sealant, and tighten again. Once zero leaks are verified, ignite the grill burners one by one and visually inspect the flame characteristics, which should burn with a stable, quiet blue flame featuring minimal yellow tips.


Can you convert a Broil King natural gas grill to propane? - Pastime ...

Can you convert a Broil King natural gas grill to propane? - Pastime ...

Technical Specifications and Component Parameters



Fuel Type Operating Pressure (Water Column) Orifice Bore Size (Relative Comparison) BTU Output Delivery Supply Hose Requirement
Liquid Propane (LP) 11.0 to 13.0 inches W.C. Smaller diameter (High pressure, low volume) Standard manufacturer rating High-pressure hose with ACME nut
Natural Gas (NG) 4.0 to 7.0 inches W.C. Larger diameter (Low pressure, high volume) Approximately 10% to 15% lower without specialized tuning Low-pressure hose with quick-disconnect

Troubleshooting Common Conversion Complications



  • Weak Flames and Low Heat Output:

    • Root Cause: Using original LP orifices with natural gas, or an undersized supply line that starves the grill of volume.
    • Actionable Fix: Verify that all LP orifices were successfully replaced with the correct NG sizing chart numbers, and ensure your natural gas supply line is at least 1/2-inch in diameter for runs under 50 feet.
  • Yellow, Sooty Flames and Black Residue:

    • Root Cause: Incorrect air shutter adjustment on the burner venturi tubes, restricting proper oxygen intake during combustion.
    • Actionable Fix: Loosen the air shutter screw on each burner tube and adjust the opening to allow more air mixing until the flames burn primarily blue with crisp tips.
  • Gas Odor Detected Near Control Knobs:

    • Root Cause: Loose valve-to-manifold connections or damaged O-rings within the control valve assembly.
    • Actionable Fix: Perform a soap test to isolate the exact source, shut off the gas supply, tighten fittings, or replace damaged valves with certified replacement parts.

Frequently Asked Questions



Can I drill out my existing propane orifices to make them work for natural gas?

No, manually drilling out propane orifices to convert them to natural gas is extremely dangerous and strictly discouraged. Factory natural gas orifices are precision-machined to exacting flow diameters and tolerances; hand-drilling can easily create uneven bores, structural weakening, or uncontrollable gas flow that leads to dangerous flare-ups.



Why does a natural gas grill require a larger orifice than a propane grill?

Natural gas is delivered at significantly lower pressure than liquid propane stored in cylinders. To achieve the correct volume of fuel required to generate adequate cooking heat at this low pressure, the opening through which the gas flows must be physically larger than a propane orifice.



Can I run a natural gas grill using a portable natural gas tank?

Unlike propane, which can be easily compressed into portable steel cylinders, natural gas is supplied continuously via underground municipal utility lines. There are no standard portable high-pressure tanks for raw natural gas, meaning your converted grill must remain tethered to a permanent home supply line.



Will converting my grill to natural gas void the manufacturer warranty?

Using unapproved third-party conversion parts or modifying a grill against manufacturer specifications will typically void the factory warranty. Always purchase an official conversion kit designed specifically by your grill's manufacturer to maintain compliance and structural safety integrity.

Upgrade Your Outdoor Cooking Experience Today

Streamline your backyard culinary setup by eliminating empty propane tank runs with a permanent, seamless natural gas utility connection. Secure your certified conversion components today and enjoy uninterrupted, reliable grilling performance all season long.


Converting A Blackstone Griddle From Propane To Natural Gas at Alyssa ...

Converting A Blackstone Griddle From Propane To Natural Gas at Alyssa ...

Read also: New global partnerships will soon expand the reach of the petc