How To Change Time On Citizen Eco-Drive: A Complete Step-by-Step Manual

How To Change Time On Citizen Eco-Drive: A Complete Step-by-Step Manual

How To Set The Time On A Citizen Eco Drive Watch Wr100 at Liza Tubbs blog

To change the time on a standard Citizen Eco-Drive watch, unscrew the crown if applicable, pull it out two clicks to Position 2, and rotate it clockwise or counterclockwise until the hands point to the correct time while observing the date change to ensure proper AM/PM orientation. For multi-function, atomic, or perpetual calendar models, you must first select your local home city code to trigger automatic hands alignment before performing any manual fine-tuning. Once adjusted, push the crown firmly back into Position 0 to secure the case against dust and moisture infiltration.


Pre-Adjustment Diagnostics & Caliber Verification

Before attempting to adjust the time on your Citizen Eco-Drive timepiece, you must establish its current operational state and identify its specific internal movement mechanism, known as the caliber. Because Eco-Drive watches run on light energy stored in a secondary titanium lithium-ion cell, performing time-setting operations while the watch is in a low-power state can desynchronize the gear train or cause the movement to halt entirely.

To determine if your watch is ready for adjustment, observe the motion of the second hand. If it is advancing normally in one-second increments, the watch has sufficient charge. If it is jumping in two-second intervals, the movement is in its Low Charge Warning state, and you must charge it under a bright light source before setting the time.

To locate the caliber number, turn the watch over and examine the engraved caseback. Look for a string of alphanumeric characters formatted as a four-character prefix followed by a hyphen and a six- or seven-character serial number (for example, E111-S022241 or H800-T014121). The first four characters ("E111" or "H800") designate the movement caliber. Knowing this caliber family ensures you apply the correct technical steps for your specific watch variant.



Tool & Preparation Checklist



  • Work Surface: A soft microfiber cloth or felt watch pad to protect the watch crystal and polished case finish from abrasions.
  • Correction Tool: A wooden toothpick or plastic pusher tool (only required for multi-function models featuring recessed correction buttons).
  • Lighting: A bright, cool LED light source or indirect sunlight to verify hand alignment and charge status.
  • Prerequisite Knowledge: Location of the caliber number on the caseback and confirmation that the second hand is not skipping in two-second intervals.
  • Estimated Duration: 3 to 8 minutes depending on caliber complexity.
  • Required Budget: $0 (no specialized watchmaking tools required).

Step-by-Step Instructions to Adjust Your Eco-Drive Watch

Citizen Eco-Drive movements are categorized into three main architectures: standard three-hand models with simple date windows, multi-function chronographs with calendar indicators, and radio-controlled/atomic timekeeping models. Follow the corresponding procedural steps below for your specific model type.



Step 1: Inspect and Unlock the Crown Mechanism

Before pulling the crown outward, check if your watch features a screw-down crown, which is common in professional dive models like the Promaster series to ensure water resistance.



  1. Grasp the crown between your thumb and forefinger.
  2. Gently rotate the crown counterclockwise (toward you). If the crown backs out on threaded tracks, continue turning until it springs slightly outward from the case. This is Position 0 (unlocked).
  3. If the crown rotates freely without backing out, your watch does not have a screw-down crown and is already in Position 0.

Warning: Do not force or pull the crown outward while it is still threaded into the case pipe. Applying axial force to a locked screw-down crown can strip the internal threads or bend the winding stem, rendering the watch water-compromised and requiring professional repair.



Step 2: Set the AM/PM Orientation (Standard 3-Hand Movements)

To prevent the watch calendar from advancing at 12:00 PM (noon) instead of 12:00 AM (midnight), you must establish the watch's internal AM/PM orientation before setting the exact time.



  1. Pull the crown out two clicks to Position 2 (the outermost position). The second hand will stop moving instantly on most calibers, allowing for precise synchronization.
  2. Rotate the crown clockwise (away from you) to advance the hour and minute hands.
  3. Watch the date window as the hands pass the 12 o'clock position. If the date indicator disc clicks over to the next day, the watch has reached 12:00 AM (midnight). If the date does not change, the watch is passing 12:00 PM (noon).
  4. Advance the hands past the midnight threshold until they reach 6:00 AM. This safely positions the movement outside of the date-change gear-engagement window, which typically occurs between 9:00 PM and 4:00 AM.


Step 3: Calibrate the Date and Day Indicators

With the watch safely positioned at 6:00 AM, you can now set the calendar without risking damage to the delicate calendar advancement teeth.



  1. Push the crown in one click to Position 1 (the middle position).
  2. Rotate the crown counterclockwise to advance the date window until it displays yesterday's date.
  3. If your watch features a day-of-the-week indicator dial or window, rotate the crown clockwise to advance the day until it shows yesterday's day.
  4. Pull the crown back out one click to Position 2.
  5. Rotate the crown clockwise to advance the time forward. Watch the calendar display turn over to today's correct date and day. Once it clicks over, you are officially in the AM phase of the current day.
  6. Continue rotating the hands forward until you reach the exact current time. If setting the watch in the afternoon, advance the hands past the 12 o'clock mark once more to enter the PM phase.

Pro-Tip: Adjusting the quick-set date when the watch hands are positioned between 9:00 PM and 4:00 AM can jam the calendar mechanism. The date jumper gears are actively engaged during these hours. Always move the hands to 6:00 AM before altering the date independently.



Step 4: Finalize and Lock the Winding Stem

To complete the adjustment process on standard models, you must secure the crown to maintain the watch's hermetic seal.



  1. Wait for your reference time source (such as an atomic clock or mobile device) to reach exactly 00 seconds.
  2. At that exact second, push the crown firmly back into the case to Position 0. The second hand will resume its sweeps immediately.
  3. For models with screw-down crowns, apply gentle pressure inward toward the case while rotating the crown clockwise. Once the threads catch, screw it down snugly. Do not overtighten, as this can crush the internal rubber O-ring gasket.


Step 5: Adjusting Atomic, Satellite Wave, and Radio-Controlled Models

Radio-controlled Citizen Eco-Drive models (such as the H800, H145, or U680 calibers) use radio waves to set the time automatically. However, if the time is off or if you travel, you must manually adjust the home city setting.



  1. Pull the crown out one click to Position 1. The second hand will sweep to point to the current city code abbreviated along the outer dial ring or dial bezel (e.g., NYC for New York, LON for London, TYO for Tokyo).
  2. Rotate the crown clockwise or counterclockwise to move the second hand to your desired local home city code.
  3. As you select a new city, the hour, minute, and 24-hour hands will automatically begin moving to the correct time zone using internal memory.
  4. To toggle Daylight Saving Time (DST) or Summer Time, press and release the lower-right push button on the side of the case. The second hand will swing to indicate "ON" or "OFF" on the dial markers.
  5. Push the crown back in to Position 0 once the hands stop moving. The watch will now maintain atomic synchronization based on the newly selected geographical transmitter.

How To Set Time On Citizen Eco Drive Radio Controlled Red Arrows at ...

How To Set Time On Citizen Eco Drive Radio Controlled Red Arrows at ...

Citizen Eco-Drive Caliber Specifications & Setting Matrix

The table below outlines the core technical specifications, crown positions, and default operational steps across the most common Citizen Eco-Drive caliber families. Refer to your specific caseback caliber code to find your model's exact parameters.



Caliber Family Common Model Types Crown Position 1 Function Crown Position 2 Function Synchronous Manual Alignment (All-Reset)
E101, E111, J810 Basic 3-Hand Dress & Field Watches Quick-Set Date (Counterclockwise) / Quick-Set Day (Clockwise) Manual Hour and Minute Setting (Stops Second Hand) Push crown to Position 0; no software reset required for mechanical date wheels.
H500, H573 Chronograph & Date Sports Watches Quick-Set Date (Counterclockwise rotation only) Main Time Setting (Synchronizes 24-Hour Sub-dial) Pull crown to Position 2, hold top and bottom pushers for 2 seconds, then push to Position 0.
E820, E870 Perpetual Calendar & Chronograph Mode Selection (Time, Calendar, Alarm, Local Time) Parameter Adjustments (Alters selected mode values) Set mode to "TME", pull crown to Position 2, short-circuit pushers to align hands to 12:00.
H800, H820 Multi-Band Atomic Radio-Controlled Home City Selection & DST On/Off Toggle Manual Time Setting (Override of atomic sync) Pull crown to Position 2, hold both pushers for 4 seconds. Hands will align to their physical zero index.
F150, F900 Satellite Wave GPS Timekeeping Manual Time Zone Selection (Using second hand pointer) Manual Time and Calendar Correction Pull crown to Position 2, hold upper-right pusher for 2 seconds to initiate GPS zero-point check.

Diagnostics & Recovery for Unresponsive Eco-Drive Movements

If your Eco-Drive watch exhibits unexpected behavior during or after a time adjustment, the quartz movement may have suffered an operational interruption. Use the troubleshooting steps below to resolve these common issues.



Case 1: The second hand jumps in two-second intervals and refuses to set



  • Root Cause: The watch is experiencing an extreme power deficit. When the charge in the secondary lithium cell drops below a critical threshold, the movement enters an energy-saving state to conserve the remaining power. It will not allow time-setting operations to register correctly.
  • Actionable Fix: Expose the watch dial directly to sunlight. Place the watch on a windowsill or under an LED desk lamp (at least 8 inches away to avoid heat damage). For a full charge from a completely dead state, the watch requires approximately 11 hours of direct sunlight (100,000 lux) or up to 120 hours under standard indoor fluorescent lighting (3,000 lux). Avoid placing the watch on a car dashboard, as excessive heat can deform internal components.


Case 2: The watch date changes exactly at 12:00 PM (noon)



  • Root Cause: The internal hand orientation is exactly 12 hours out of sync. The watch movement registers noon as midnight because the hands were set without verifying the AM/PM date turnover threshold.
  • Actionable Fix: Pull the crown out to Position 2. Rotate the hands clockwise 12 full hours (one complete rotation of the hour hand). Push the crown back in to Position 0. The next date transition will now occur at midnight.


Case 3: The hands remain stationary after setting the time and pushing the crown in



  • Root Cause: The watch has entered a deep "Power Save Mode" due to prolonged lack of light exposure, or the internal integrated circuit (IC) needs a system reset following a total power drain.
  • Actionable Fix: Perform an "All-Reset" procedure. For most standard calibers, pull the crown out to Position 2. Press and hold all side-mounted push buttons simultaneously for 3 to 5 seconds, then release them. Push the crown back in to Position 0. Expose the watch to direct sunlight for 30 minutes to jump-start the movement, then proceed with the standard time-setting steps.


Case 4: The radio-controlled time is incorrect by exactly one or more hours



  • Root Cause: The watch is referencing the incorrect home city, or the Daylight Saving Time (DST) setting is out of sync with your local region's current laws.
  • Actionable Fix: Pull the crown out to Position 1. Check where the second hand points. If you are on the East Coast of the United States and the hand points to "CHI" (Chicago) or "LAX" (Los Angeles) instead of "NYC" (New York), rotate the crown to correct the city code. Next, press the lower pusher to toggle the DST indicator to match your current local status, then push the crown back in to Position 0.

Frequently Asked Questions



How do I know if my Citizen Eco-Drive is fully charged?

On models equipped with a power reserve indicator sub-dial, the charge level is displayed via an analog scale pointing from a low-power icon to a full-power icon. On standard three-hand models without an indicator, you can verify a healthy charge by observing the second hand: if it moves smoothly in precise, one-second intervals, the watch has a sufficient charge.



Why is my Citizen Eco-Drive watch running slow?

Unlike mechanical watches, a quartz-regulated Citizen Eco-Drive will not gradually slow down due to gravity or mainspring tension. If it is losing time, it is almost always due to an insufficient charge state triggering the low-power conservation mode, or exposure to a strong magnetic field (such as from laptops, magnetic clasps, or speakers) which temporarily disrupts the stepper motor.



Do I need to wind my Citizen Eco-Drive watch?

No, Eco-Drive watches do not use a mechanical mainspring and cannot be manually wound via the crown to generate power. Turning the crown in Position 0 will simply spin it freely without resistance. The watch relies entirely on light passing through the semi-transparent dial to generate electricity via its underlying solar cell.



What does the "RX", "NO", and "OK" mean on my watch dial?

These markings indicate the status of the radio-controlled time synchronization. "RX" (Receiving) means the watch is currently actively searching for or downloading a calibration signal. "OK" indicates that the most recent synchronization attempt was successful, while "NO" indicates that the watch failed to receive a clear signal during its nightly update window.

Maintain Your Precision Timepiece

Proper time setting and regular light exposure will keep your Citizen Eco-Drive watch running reliably for decades. If your timepiece continues to show inaccurate time or remains unresponsive after a full solar charge and an All-Reset procedure, it may require a gasket replacement or a new secondary battery cell. Contact an authorized Citizen service center to restore your watch's factory performance standards.


How To Change Time On Citizen Eco Drive : When the watch shows around ...

How To Change Time On Citizen Eco Drive : When the watch shows around ...

Read also: How to Sew Binding on a Quilt: A Professional Guide to Perfect Finishes