Mastering an Aube thermostat requires understanding its unique interface, whether you are operating a line-voltage heating control or a low-voltage programmable model. By navigating the programming menus, setting precise heating schedules, and utilizing override functions, you can optimize your home energy efficiency while maintaining optimal thermal comfort.


Pre-Operation and Equipment Checklist

Operating an Aube electronic thermostat efficiently depends on recognizing your specific unit model, verifying wiring infrastructure, and understanding baseline programming conventions. Aube technologies, often integrated into Honeywell Home lines, span non-programmable, 7-day programmable, and 5-2 day programmable configurations designed for baseboards, convectors, or central HVAC systems.



  • Essential Equipment and References: Current model user manual, small flathead screwdriver (if accessing battery compartments or wiring terminal blocks), and fresh alkaline batteries (for low-voltage models requiring backup power).
  • Mandatory Prerequisite Knowledge: Familiarity with Celsius versus Fahrenheit temperature scales, understanding of the difference between permanent hold (manual mode) and automatic scheduled programming, and basic awareness of anticipated comfort setpoints.
  • Time and Scope Benchmarks: Initial configuration takes roughly 5 to 10 minutes; routine schedule adjustments require 2 to 3 minutes per heating cycle.

Step-by-Step Aube Thermostat Operation Workflow



Step 1: Identify Your Thermostat Model and Power Source

Locate the model number, typically found inside the battery compartment door or on the interior frame of the faceplate. Determine whether your unit controls a line-voltage system (120V to 240V, common for electric baseboards) or a low-voltage system (24V, common for furnaces and heat pumps). Line-voltage units draw power directly from the household electrical supply, while many low-voltage units rely on AA or AAA alkaline batteries.

Warning: Line-voltage Aube thermostats switch high voltage directly. Never remove the faceplate or touch terminal screws without shutting off power at the main circuit breaker panel to prevent electrical shock.



Step 2: Set the Current Time and Day of the Week

Press the Mode or Menu button until the clock icon or day indicator begins flashing on the digital LCD screen. Use the Up and Down arrow buttons to adjust the hour and minute to the current local time, paying close attention to AM and PM designations. Press the Enter, Mode, or Next button to advance to the day of the week, select the correct day using the arrows, and save your settings.

Pro-Tip: Accurate timekeeping is critical for programmable Aube models; a misaligned clock will result in heating cycles activating during unoccupied hours, driving up energy bills.



Step 3: Choose Between Manual (Hold) and Automatic Operating Modes

Locate the Mode button or slide switch to toggle between Manual mode (often designated by a hand icon or "Manual") and Auto mode (designated by a schedule icon or "Program"). In Manual mode, the thermostat maintains a single constant temperature setpoint indefinitely until you change it. In Auto mode, the thermostat follows the programmed time and temperature schedule defined in its memory.



Step 4: Program Your Heating Schedule (For Programmable Models)

Press the Program or PGM button to enter the schedule configuration menu. Select the day or block of days you wish to program, such as Monday through Friday (5-2 models) or individual days (7-day models). Adjust the setpoints for the four standard daily periods: Wake, Leave, Return, and Sleep. Use the arrow keys to select the desired start time for each period, followed by the target temperature, and press Save or Next after each entry.



Step 5: Utilize Temporary and Permanent Temperature Overrides

To temporarily override a scheduled setpoint while in Auto mode, simply press the Up or Down arrow buttons until your desired temporary temperature appears on the display. This temporary override remains active until the start of the next programmed time period. To establish a permanent hold, press the Hold button; the unit will maintain this manual temperature indefinitely until you press the Run or Auto button to resume normal scheduling.


Honeywell TH1 15-A-240D-B Aube DB Programmable Thermostat - IMS Supply

Honeywell TH1 15-A-240D-B Aube DB Programmable Thermostat - IMS Supply

Aube Thermostat Feature Comparison Matrix



Feature / Parameter Line-Voltage Models (e.g., TH132, TH135) Low-Voltage Models (e.g., TH114, TH215) Non-Programmable Models
Primary Application Electric baseboards, convectors, radiant heaters Central furnaces, boilers, heat pumps Direct manual temperature control
Power Supply 120V / 240V AC hardwired 24V AC or 2 x AA alkaline batteries Hardwired or battery powered
Control Accuracy Proportional Adaptive Cycle (prevents swings) Precision electronic temperature sensing Manual mechanical or electronic adjustment
Scheduling Capacity 7-day or 5-2 day programmable options 7-day, 5-2 day, or 24-hour schedules None (Manual hold only)

Common Operational Failures and Field Fixes



  • Root Cause: Screen is completely blank or unresponsive on a battery-operated low-voltage Aube unit.

    • Actionable Fix: Remove the thermostat faceplate and inspect the battery compartment. Replace expired AA or AAA alkaline batteries, ensuring correct polarity orientation (+/-), and verify battery contacts are free from corrosion.
  • Root Cause: The heating system fails to activate even when the setpoint is higher than the ambient room temperature.

    • Actionable Fix: Check the mode setting to ensure the unit is not set to Off or Cooling. Verify that the minimum off-time protection timer has expired (Aube thermostats often feature a built-in compressor or relay protection delay lasting 3 to 5 minutes).
  • Root Cause: Room temperature fluctuates excessively or does not match the displayed thermostat reading.

    • Actionable Fix: Ensure the thermostat is not installed in direct sunlight, near drafty doorways, or behind interior furniture. Access the advanced configuration menu to calibrate the temperature offset if the sensor requires recalibration against a trusted room thermometer.
  • Root Cause: Programmed schedule times are being ignored by the heating unit.

    • Actionable Fix: Verify that the thermostat is actively set to Auto mode rather than Manual or Permanent Hold. If the issue persists, perform a soft reset by pressing the reset pinhole button with a paperclip and re-entering your time and schedule settings.

Frequently Asked Questions



How do I change the temperature from Celsius to Fahrenheit on an Aube thermostat?

Remove the removable faceplate of the thermostat to access the configuration switches located on the back of the unit or inside the battery compartment. Locate the small slide switch labeled Celsius/Fahrenheit (C/F), toggle it to your desired temperature scale, and snap the faceplate back into place. Alternatively, some newer digital models allow this change through the software settings menu by pressing specific button combinations outlined in your manual.



What does the Early Start feature do on my Aube thermostat?

The Early Start feature calculates the time required for your heating system to reach the target temperature before your scheduled Wake or Return period begins. When enabled, the thermostat turns the heating system on early so that your home reaches the exact comfort setpoint precisely at the programmed time. You can enable or disable this feature within the advanced setup menu.



How do I lock the keypad to prevent unwanted temperature changes?

Most programmable Aube thermostats feature a keypad lockout function to prevent children or guests from altering settings. Navigate to the user settings menu or press and hold a specific combination of buttons (such as the Up and Down arrows simultaneously) for roughly 5 seconds until a lock icon appears on the screen. Repeat the process to unlock the keypad.



Why is my electric baseboard clicking when the Aube thermostat turns on?

Many line-voltage Aube thermostats utilize a silent electronic relay, but older models or specific configurations may use a mechanical relay that produces a audible click when switching high-voltage power. This clicking sound is normal operation as the internal switch opens and closes to supply current to the heating element. If the clicking is accompanied by erratic heating, verify that the load amperage does not exceed the thermostat maximum rating.



How often should I replace the batteries in a low-voltage Aube thermostat?

You should replace the batteries in your low-voltage Aube thermostat at least once a year, preferably at the start of the heating season. When battery voltage drops below operational thresholds, a low battery indicator icon will flash on the LCD screen, signaling that immediate replacement is required to prevent system shutdown.

Master your home heating system today by applying these precise Aube thermostat programming steps for maximum efficiency and comfort.


Aube PB112-024T - In-Floor Heating Thermostat - Devices - Hubitat

Aube PB112-024T - In-Floor Heating Thermostat - Devices - Hubitat

Read also: What is 2 2 3 schedule impacts on your work-life balance revealed