Comprehensive Guide: How To Apply Rolled Asphalt Roofing For Residential And Commercial Flat Roofs

Comprehensive Guide: How To Apply Rolled Asphalt Roofing For Residential And Commercial Flat Roofs

Types of Asphalt Roofing | ARMA

Applying rolled asphalt roofing requires precision in surface preparation, material acclimation, and systematic adhesive application to ensure a watertight seal on low-slope structures. By adhering to a strict overlap protocol and utilizing professional-grade roofing cement, you can effectively waterproof surfaces with slopes between 1:12 and 4:12, achieving a standard lifespan of 10 to 15 years.


Pre-Installation Site Requirements and Tooling Strategy

Success in roofing begins long before the first roll is unfurled. Rolled asphalt roofing—often referred to as mineral-surfaced roll roofing—is designed specifically for low-slope applications where shingles are ineffective due to water backup risks. Before beginning, ensure the roof deck is structurally sound, clean, and completely dry. Moisture trapped beneath the membrane will cause blistering and premature delamination.



  • Essential Equipment: Utility knife with a substantial supply of heavy-duty hook blades, a 12-inch wide wallpaper seam roller or heavy weighted floor roller, a serrated roofing trowel, a chalk line, and a roofing hammer.
  • Material Requirements: Mineral-surfaced rolled asphalt, plastic roofing cement (mastic) designed for asphalt products, 1-inch to 1.5-inch galvanized roofing nails with large heads, and high-quality asphalt primer if the surface is porous.
  • Safety Standards: Use OSHA-compliant fall protection systems for all work performed above 6 feet, regardless of the slope. Ensure weather conditions are dry with temperatures between 50°F and 90°F to allow the material to remain pliable without becoming excessively soft or tacky.
  • Budgetary Benchmarks: Professional-grade results typically require a budget allowing for 10% waste overhead to account for edge trimming and flashing overlaps.

Procedural Workflow: Systematic Application Techniques



Step 1: Surface Preparation and Primer Application

Remove all existing debris, protruding nails, and loose aggregate from the roof deck. If you are installing over an old layer of roofing, ensure it is smooth and free of major irregularities. Apply a thin, uniform layer of asphalt primer if you are working over concrete or aged wood, allowing it to cure completely before moving to the membrane application. Snap a chalk line parallel to the eave, offset by the width of your roll minus two inches, to serve as a guide for the first course.



Step 2: Unrolling and Initial Acclimation

Roll out the roofing material and allow it to relax for at least 30 minutes in direct sunlight. This step is critical; it releases the internal stresses from the manufacturing spool and prevents the edges from curling upward after installation. If the material is cold, it will be brittle and prone to cracking during installation.



Step 3: Fastening the Starter Course

Align the bottom edge of the first sheet along the chalk line, ensuring a 1-inch overhang at the eaves to facilitate water shedding into the gutter system. Secure the top edge of the sheet using galvanized roofing nails spaced 6 inches apart, driven through the “nailing strip” (the non-granulated edge of the roll).

Warning: Do not over-drive the nails. They should sit flush against the membrane surface. Driving them too deep will fracture the asphalt coating, creating a direct pathway for water infiltration.



Step 4: Applying Adhesive and Lapping Courses

Apply a continuous, 4-inch wide bead of roofing cement along the overlap area of the previous sheet. Unroll the second course, overlapping the first by at least 3 inches, or as specified by the manufacturer. Press the seam firmly with a weighted roller to ensure complete contact. Repeat this process until you reach the peak of the roof.

Pro-Tip: Always install sheets from the bottom of the roof toward the top (eave to ridge) to ensure that the overlapping edge faces downstream, preventing water from flowing under the seam.



Step 5: Sealing Valleys, Ridges, and Penetrations

For ridges, cut the material into 12-inch wide strips and fold them over the peak, embedding them in a bed of asphalt mastic. For roof penetrations like vents or chimneys, build a “cantu” or curb using flashing cement, and wrap the membrane tightly around the base, securing it with mechanical fasteners before covering with a final layer of mastic for a seamless finish.


Everything You Need to Know About Asphalt Roofing

Everything You Need to Know About Asphalt Roofing

Technical Specifications and Material Performance Parameters



Feature Mineral-Surfaced Roll Smooth-Surfaced Roll
Primary Use Finished residential roofing Base layer/flashing
Minimum Slope 1:12 (1 inch per foot) 2:12
Estimated Lifespan 10–15 Years 5–8 Years
UV Resistance High (Granular coating) Low (Needs coating)
Installation Temp 50°F – 90°F 50°F – 90°F

Troubleshooting Common Field Failures



  • Root Cause: Blistering. Trapped air or moisture under the membrane expands under heat, forcing the asphalt to lift.

    • Actionable Fix: Cut the blister with a utility knife in an X-pattern, fold back the edges, apply roofing cement underneath, press flat, and seal the top with additional mastic and granules.
  • Root Cause: Seam Separation. Inadequate adhesive application or failure to roll the seams during the initial installation.

    • Actionable Fix: Clean the area with mineral spirits, allow it to dry, apply a generous amount of roofing mastic, and use a heavy-duty roller to re-bond the materials.
  • Root Cause: Buckling/Wrinkling. Material was installed too quickly without allowing for proper “relaxation” time, or the deck was improperly nailed.

    • Actionable Fix: In mild cases, minor wrinkles can be smoothed with a heat gun and roller. Severe buckling usually requires cutting out the affected section and patching with a new piece of membrane.

Frequently Asked Questions



Can I install rolled asphalt roofing directly over shingles?

It is generally discouraged. The irregular surface of shingles prevents a smooth bond, which leads to early failure. It is best practice to strip the old shingles to ensure a clean, flat substrate.



What is the ideal overlap width for rolled roofing?

A 3-inch overlap is the industry standard for longitudinal seams. For end laps where one roll finishes and another begins, you must increase this overlap to 6 inches to ensure a secondary layer of protection against capillary action.



Does the color of the rolled roofing affect performance?

While color primarily impacts aesthetics, lighter-colored granules offer better thermal reflectivity, which can slightly reduce heat absorption on the roof deck, extending the material's service life.



How do I handle chimney flashing with this material?

Always use metal flashing (galvanized or aluminum) at the chimney base. The rolled roofing should terminate against the vertical metal surface, sealed with a bead of roofing cement, and covered with a metal counter-flashing.

Ensure Your Structural Integrity Today

Properly applied rolled asphalt roofing provides an affordable and highly effective defense against the elements for your outbuildings or low-slope sections. Contact a certified roofing professional today to verify your deck's load-bearing capacity and ensure your installation meets all local building codes.


How To Install Roll Roofing

How To Install Roll Roofing

Read also: You might find a how to track a ups package secret feature