How To Adjust Humidity On ResMed AirSense 11: Step-by-Step CPAP Comfort Guide

How To Adjust Humidity On ResMed AirSense 11: Step-by-Step CPAP Comfort Guide

Buy ResMed AirSense 11 AutoSet CPAP Device at Air Voel

To adjust the humidity on your ResMed AirSense 11, tap My Options on the touchscreen, select Climate Control, and switch it to Manual. Once in manual mode, tap Humidity Level and rotate or tap the screen to select a setting from Off to 8, aiming for a baseline of 4 to balance moisture delivery and prevent tubing condensation.

A properly calibrated humidification system is one of the most critical factors in maintaining CPAP therapy compliance. When therapy air is dry, it can strip moisture from your nasal passages and oral airway, leading to dry mouth, nasal congestion, nosebleeds, and increased airway resistance.

Conversely, setting the humidity too high without balancing the ambient temperature can cause "rainout"—a phenomenon where warm, moisture-laden air cools inside your tubing, condensing into water droplets that can splash onto your face or create a loud gurgling noise.

The ResMed AirSense 11 features advanced climate control algorithms designed to prevent these issues. However, finding your personal comfort zone often requires transitioning from the machine’s default automated settings to precise, manual adjustments.


Essential CPAP Components and Environmental Pre-Setup

Before modifying any settings on your medical device, you must ensure that your hardware is properly assembled, positioned, and filled. Adjusting digital settings on a dry water chamber or with incompatible tubing can trigger system errors or fail to deliver the desired clinical therapeutic outcomes.



Preparation Checklist



  • Essential Gear & Hardware:

    • ResMed AirSense 11 CPAP machine (AutoSet, CPAP, or Elite model).
    • HumidAir 11 cleanable or standard water tub.
    • ClimateLineAir 11 heated tubing (highly recommended for optimal humidity control) or a standard SlimLine/Standard non-heated tube.
    • Pure distilled water (mandatory to prevent mineral scaling and prolong the lifespan of the heater plate).
  • Mandatory Prerequisite Knowledge:

    • Understand the difference between Climate Control Auto and Climate Control Manual. Auto mode requires a ClimateLineAir 11 heated tube and maintains a fixed relative humidity of 85% at a target temperature of 80 degrees Fahrenheit (27 degrees Celsius). Manual mode allows you to adjust the tube temperature and humidity levels independently.
  • Time & Cost Benchmarks:

    • Estimated Duration: 3 to 5 minutes.
    • Estimated Cost: 0 USD (assuming you already own the machine and heated tubing).

How to Adjust Humidity on ResMed AirSense 11: The Complete Walkthrough

The ResMed AirSense 11 utilizes a high-resolution color touchscreen, representing a significant upgrade from the physical dial interface of the AirSense 10. Follow these precise steps to access and customize your humidification levels.



Step 1: Power On and Access the Home Screen

Ensure your AirSense 11 is plugged into a stable power source using the proprietary 65W AC power adapter. The touchscreen should light up, displaying the home screen. If the screen is black, gently tap anywhere on the glass interface to wake the system. The home screen displays two primary icons: "My Options" and "More".



Step 2: Navigate to the My Options Menu

Tap the My Options button (indicated by a gear icon) on the touchscreen. This action opens the clinical user preferences menu, where you can modify comfort settings without entering the clinical provider menu.



Step 3: Change Climate Control from Auto to Manual

If you are using a ClimateLineAir 11 heated hose, the machine defaults to Climate Control Auto. In this mode, the manual humidity adjustment scale is locked and hidden from view.



  1. Scroll down the menu by swiping up on the touchscreen until you locate the Climate Control parameter.
  2. Tap Climate Control.
  3. Select Manual from the pop-up options.
  4. Confirm your selection. Once switched to Manual, two previously hidden sub-menus will appear immediately below: Tube Temp and Humidity Level.

Pro-Tip: If you are using a standard, non-heated SlimLine tube, the machine cannot support Climate Control Auto. The machine will automatically display the manual Humidity Level option by default, and the Tube Temp option will remain unavailable.



Step 4: Adjust the Humidifier Output (Humidity Level 1 to 8)

With Climate Control set to Manual, you can now directly adjust the moisture output of your HumidAir 11 tub.



  1. Tap Humidity Level on the touchscreen.
  2. You will see a linear scale ranging from Off to 8.
  3. Tap the plus (+) or minus (-) icons on the screen, or drag your finger along the slider to select your desired level.
  4. Tap OK to save and lock in your selection.

Warning: Do not increase the humidity level above 5 if you are using a non-heated tube in a cold bedroom (below 68 degrees Fahrenheit / 20 degrees Celsius). Doing so will rapidly cause heavy condensation and rainout in your tube, which can wake you up with splashing water.



Step 5: Adjust the ClimateLineAir 11 Tube Temperature (Optional)

If you are utilizing the heated ClimateLineAir 11 hose, you must balance your physical humidity setting with a matching tube temperature to prevent condensation.



  1. Tap Tube Temp from the My Options menu.
  2. Select a temperature setting ranging from 60°F to 86°F (16°C to 30°C).
  3. Tap OK to confirm your selection.
  4. As a rule of physical science, higher humidity settings (6 to 8) require higher tube temperatures (78°F to 84°F) to prevent the air from cooling to its dew point before it reaches your mask.


Step 6: Verify and Initiate Therapy

Press the Start Therapy/Standby physical button on the top of the AirSense 11. Lie down in your normal sleeping position and test the air temperature and moisture level for 2 to 3 minutes. If you experience dry nasal passages, prepare to increase the setting by one increment the following night. If you notice water accumulation in your mask, prepare to lower the humidity or raise the tube temperature.


ResMed AirSense 11 AutoSet - Advanced Auto-adjusting CPAP Machine ...

ResMed AirSense 11 AutoSet - Advanced Auto-adjusting CPAP Machine ...

ResMed AirSense 11 Humidity Settings and Temperature Matrix

The following reference table outlines the technical parameters, target environments, and recommended configurations for different ambient bedroom conditions. Use this matrix as a clinical baseline for configuring your equipment.



Humidifier Setting Equivalent Relative Humidity Recommended Tube Temp (ClimateLineAir 11) Recommended Ambient Room Temp Clinical Use Case & Indications
Off Ambient Room Humidity (No active heat) Off / No Heat Any Temperature Patients experiencing zero dryness; operating the machine in highly humid tropical climates.
1 – 3 (Low) ~40% to 55% RH 64°F to 72°F (18°C to 22°C) Warm Rooms (> 75°F / 24°C) Mild dryness; ideal for summer months or naturally humid geographical zones.
4 – 5 (Medium) ~60% to 75% RH 74°F to 78°F (23°C to 26°C) Moderate Rooms (68°F to 72°F) Default starting range; balances mucosal hydration with minimal risk of rainout.
6 – 8 (High) ~80% to 95% RH 80°F to 86°F (27°C to 30°C) Cool/Cold Rooms (< 65°F / 18°C) Severe dry mouth, nasal congestion, cold symptoms, or during winter in dry climates.
Auto Mode Stable 85% RH Automatically set to 80°F (27°C) Dynamic/Variable Standard recommended clinical setting; provides constant adaptation to changing room conditions.

Resolving Common CPAP Humidity Failures and Rainout Issues

Even with premium CPAP hardware, fluctuating environmental conditions, HVAC cycling, and physiological variables can disrupt your therapy. Below are the most common real-world humidification failures on the ResMed AirSense 11 and how to resolve them.



Scenario 1: Excess Water Accumulating in the Tube or Mask (Rainout)



  • Root Cause: The air delivered by the heated humidifier is holding more moisture than the physical temperature of the room air can support. As the warm, moist air travels down the tube toward your mask, the cooler room air drops the temperature inside the tube below the dew point, causing the gaseous moisture to liquify.
  • Actionable Fix: First, if using manual mode, increase your Tube Temp setting by 2 to 4 degrees Fahrenheit to keep the air warm until it reaches your mask. Alternatively, reduce your Humidity Level setting down by one or two increments. If you are using a non-heated tube, you must upgrade to a ClimateLineAir 11 heated tube, or use a fleece insulated tubing wrap to shield the hose from cold ambient room air.


Scenario 2: Persistent Dry Mouth or Burning Nasal Passages



  • Root Cause: The mucosal membranes of the nose and throat are drying out due to insufficient humidification. This can occur because the manual humidity setting is configured too low, the water chamber is running completely dry during the night, or you are experiencing mouth-breathing while using a nasal mask (causing pressurized air to escape through your open mouth, stripping moisture instantly).
  • Actionable Fix: Step up your manual Humidity Level setting to 5 or 6. If you are using a nasal or nasal pillows mask, wear a chin strap to keep your mouth closed, or consult your clinician about transitioning to a full-face mask. Ensure your water chamber is filled to the maximum limit line with fresh distilled water before going to sleep.


Scenario 3: The HumidAir 11 Water Tub Empties Too Quickly



  • Root Cause: Your humidifier is depleting its entire 380 mL water capacity before your sleep cycle ends. This is typically driven by a high therapy pressure setting (above 12 cm H2O), a very high humidity setting (7 or 8), or a substantial, uncorrected mask leak. Mask leaks force the machine to ramp up airflow to maintain therapy pressure, which rapidly accelerates water evaporation.
  • Actionable Fix: Check your mask fit and run the "Mask Fit" diagnostic on your AirSense 11 to eliminate leaks. If leaks are under control, transition your Climate Control back to Auto mode, which dynamically throttles water usage based on real-time ambient monitoring, extending water life. If you must run manual mode, lower your humidity setting to 4 or 5 and lower the room heating to reduce the evaporation rate.


Scenario 4: "Heating System Error" or Unwarmed Air Output



  • Root Cause: The AirSense 11 is failing to engage the heating plate located beneath the HumidAir 11 water tub. This can occur if the water tub is not completely seated in the device, if the electrical contacts on the bottom-rear of the tub are dirty or wet, or if there is an internal system error.
  • Actionable Fix: Power down the CPAP machine by unplugging the power cord. Pull the HumidAir 11 water tub completely out of the machine. Inspect the brass-colored heating plate on the machine base and the corresponding metallic contacts on the tub. Wipe them dry with a clean microfiber cloth. Firmly slide the tub back into the slot until you hear a clear mechanical click. Plug the power source back in and restart the therapy.

Frequently Asked Questions



Should I use Auto or Manual Climate Control on the AirSense 11?

For the vast majority of CPAP users, Climate Control Auto is the superior option because it dynamically monitors room temperature and relative humidity to prevent rainout while maintaining constant moisture. You should only switch to Manual if you continue to experience dry mouth on Auto mode, or if you prefer a cooler air temperature than the default 80 degrees Fahrenheit (27 degrees Celsius) that Auto mode maintains.



Why can't I see the humidity setting on my AirSense 11?

If the manual humidity setting is not visible in your My Options menu, it means your machine has a ClimateLineAir 11 heated tube attached and the Climate Control parameter is set to Auto. To reveal the manual humidity slider, you must tap Climate Control on the screen and change it from Auto to Manual.



What is the best humidity setting for CPAP to prevent dry mouth?

A manual setting of 4 or 5 is the recommended baseline starting point for most climates. If you still experience dry mouth at this level, increase the setting to 6 or 7, while simultaneously raising your heated tube temperature to at least 78 degrees Fahrenheit (26 degrees Celsius) to prevent condensation.



Can I run my AirSense 11 without water in the humidifier?

Yes, you can run your AirSense 11 without water, but you must navigate to the My Options menu and turn the Humidity Level to Off. Running the machine with an empty water tub while the heater plate is still active will not damage the machine, but it can produce a warm, plastic-like smell and will deliver highly uncomfortable, dry therapeutic air.



How often should I clean the HumidAir 11 water tub?

You should empty any remaining water from the tub daily, rinse it thoroughly, and allow it to air-dry out of direct sunlight to prevent bacterial growth. Once a week, perform a deep clean by soaking the tub in a mixture of one part white vinegar to five parts warm water for 30 minutes, then rinse it with clean water and dry.

Optimize Your Sleep Therapy Today

Taking control of your CPAP therapy settings is the key to achieving deeper, restorative sleep without airway irritation. If you continue to experience persistent dry mouth or severe condensation after optimizing your ResMed AirSense 11 settings, reach out to your sleep physician or clinical equipment provider to evaluate your mask seal and therapeutic pressure options.